$ heat-pump --live

Romsey · Vitocal 200-A 8 kW

I spend my working days looking at other people's heat pump data, so it seemed only fair to publish my own. Everything here comes straight from MID-certified heat and electricity meters on the system, read every 10 seconds by an OpenEnergyMonitor emonHP.

Connecting…

Heat out

–kW

Electricity in

–kW

COP now

–

no live data

Flow / return

–°C

Room

–°C

Outside

–°C

Met Office, hourly

Hot water

–°C

cylinder probe

Efficiency so far

–

since 6 Nov 2026

Last 24 hours · power

Heat outElectricity inHot water run
Loading…

Last 24 hours · temperatures

FlowReturnCylinderRoomOutsideHot water run
Loading…

Day by day

Heat outElectricity in

The first full day of data lands on 7 November.

The system

Heat pump
Viessmann Vitocal 200-A, 8 kW, R290, fitted 1 November 2026
Replaced
Samsung 12 kW, vastly oversized for the house
House
1960s semi-detached, 89 m², filled cavity walls, 270 mm loft
Design
5 kW heat loss at −2 °C, 45 °C flow, new radiators
Hydraulics
Straight through: no buffer, no low-loss header
Hot water
300 L cylinder, 50 °C, weekly legionella cycle
Controls
Viessmann ViCare
Installer
Heat Geek
Monitoring
OpenEnergyMonitor emonHP: SDM120 electricity meter and Axioma Qalcosonic heat meter, both MID class

Reading the numbers

COP is heat out divided by electricity in: 4 means four units of heat for every unit of electricity.

Totals start at 09:43 on 6 November 2026, when the electricity meter first reported. Shaded bands are hot water runs.

→ heatpumpmonitor.org → raw data on emoncms.org